Home » Product List » Switching Power supply » Switching Power Supply (MS-75)
Product Details
Switching Power Supply (MS-75)
| Model NO.: | MS-75 |
|---|
Product Description
These SMPS(Switching Power Supplys ) are widely used in the field of telecom, LED display, industrial control, laser application, TV & broadcasting, computer system, medical equipment, safety control, automotive system.
Features:
1. Low price and high reliability
2.105º C output capacitor
3. AC input power suitable for the world
4. High efficiency and low operation temperature
5. Soft-start current can reduce the AC input impact effectively
6. With short-circuit and overload protection
7. Compact size, light weight
8.100% full-load burning test
9. Installed with EMI filter, minimum wave.
| Model | MS-60-5 | MS-60-12 | MS-60-15 | MS-60-24 |
| Specification | ||||
| DC output voltage | 5V | 12V | 15V | 24V |
| Output voltage error (Note2) | ± 2% | ± 1% | ± 1% | ± 1% |
| Rated output current | 10A | 4.2A | 3.4A | 2.1A |
| Output current rage | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A |
| Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability(Note4) | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
| Load stability(Note5) | ± 1% | ± 0.5% | ± 0.5% | ± 0.5% |
| DC output power | 50W | 50.4W | 50.4W | 50.4W |
| Efficiency | 71% | 78% | 78% | 82% |
| Adjustable range for DC voltage | ± 10, -5% | ± 10% | ± 10% | ± 10% |
| AC input voltage range | 85~132VAC/170~264VACselected by switch | |||
| Input current | 2A/115V 1A/230V | |||
| AC impulse current | Cold-start current 30A/115V 60A/230V | |||
| Leakage current | < 1mA/240VAC | |||
| Overload protection | 105%~150%Type: TOLDBACK Reset: auto recovery | |||
| Over-voltage protection | … … | |||
| High-temperature protection | … … | |||
| Temperature coefficient | ± 0.03%º C(0~50º C) | |||
| Setup rise hold up time | 200ms, 100ms, 30ms | |||
| Vibration | 10~500Hz, 2G 10min. /1cycle, Period for 60min, Each axes | |||
| Withstand voltage | Input and output interval: 1.5KVAC, Input and enclosure: 1.5KVAC, Output and enclosure: 0.5KVAC | |||
| Isolation resistance | Input and output interval, Input and enclosure, Output and enclosure: 0500VAC/100M Ohms | |||
| Working temperature and humidity | -10º C~+60º C, 20%~90%RH | |||
| Store temperature and humidity | -20º C~+85º C, 10%~95RH | |||
| Overall dimension | 159*98*38mm | |||
| Weight | 0.56Kgs | |||
| Safety standards | UL1012 TUV EN60950(IEC950, UL1950)Approved | |||
| EMC standards | CLSPR22(EN55022), IEC801-2, 3, 4, IEC555-2 Verification | |||
| Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25º C 70%Rh, Humidity | ||||
| 2. Error, include the setting error, line stability and load stability. (Note: 5) | ||||
| 3. Wave test: adopting“ A12” double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting | ||||
| 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. | ||||
| 5. Load stability test: The load is from 0% to 100%, others 60%. | ||||